Simulating Particulates
AERMOD
For the calculation of particulates (PM10) AERMOD uses
- the fraction of particle mass emitted in the fine class,
less than 2.5 microns,
- the representative mass mean particle diameter in microns.
The following default values are applied:
- If no PM2.5 emissions are specified for a source, the default value of
m(PM2.5)/m(PM10) = 0.4 is used.
- Default value for mass mean particle diameter for PM2.5 (fine fraction): Dmm(PM2.5) = 2.0
- Default value for mass mean particle diameter for PM10 (coarse fraction) without PM2.5:
Dmm(PM10-PM2.5) = 7.5
- Using the default value of m(PM2.5)/m(PM10) (0.4)leads to
a default average particle diameter Dmm(PM10) = 5.3
CAMx
|